Viessmann Vitocal fault codes
What each code means, from Viessmann Vitocal's own service literature, and which UK models it applies to.
Viessmann Vitocal heat pumps
F.1Lead break, flow temp secondary/HC1F.2Short circuit, flow temp secondary/HC1F.3Lead break, secondary return tempF.4Short circuit, secondary return tempF.7Lead break, cylinder tempF.8Short circuit, cylinder tempF.13Lead break, outside temp (0°C substitute used)F.14Short circuit, outside temp (0°C substitute used)F.33Lead break, air-inlet tempF.34Short circuit, air-inlet tempF.74Hydraulic system pressure too lowF.75No flow in secondary circuit or flow sensor faultyF.87Indoor safety valve opened, system pressure too highF.91DIO electronics-module comms errorF.92ADIO electronics-module comms errorF.93M2IO electronics-module comms error6 modelsF.94SDIO electronics-module comms error6 modelsF.99PlusBus comms error (modules unavailable)6 modelsF.100PlusBus short circuitF.101PlusBus voltage errorF.102WiFi comms-module errorF.103HMI programming-unit comms error6 modelsF.104External fault-message input active (EM-EA1/DIO)6 modelsF.111Lead break, liquid-gas temp heatingF.112Short circuit, liquid-gas temp heatingF.117Lead break, evaporator suction-gas tempF.118Short circuit, evaporator suction-gas tempF.123Lead break, liquid-gas temp condenserF.124Short circuit, liquid-gas temp condenserF.147Lead break, compressor suction-gas tempF.148Short circuit, compressor suction-gas tempF.149Lead break, liquid-gas temp cooling (runs on substitute)F.150Short circuit, liquid-gas temp cooling (runs on substitute)F.151Lead break, hot-gas tempF.152Short circuit, hot-gas tempF.155Fault, electronic expansion valve 16 modelsF.156Fault, electronic expansion valve 26 modelsF.160CAN-bus general comms fault between modules6 modelsF.425Time sync not possibleF.430Gateway comms errorF.431KNX/TP gateway comms errorF.454Wrong operating-software version across modules (HPMU/EHCU/VCMU)F.472Energy-meter comms errorF.519BACnet/IP gateway comms errorF.520Modbus comms error inverter↔VCMU6 modelsF.542Lead break, flow temp HC1 with mixer (or wrong commissioning)6 modelsF.543Short circuit, flow temp HC1 with mixer6 modelsF.544Lead break, flow temp HC2 with mixerF.545Short circuit, flow temp HC2 with mixerF.546Lead break, flow temp HC3 with mixerF.547Short circuit, flow temp HC3 with mixerF.548Lead break, flow temp HC4 with mixerF.549Short circuit, flow temp HC4 with mixerF.623Lead break, return temp (mixer HC1)6 modelsF.624Short circuit, return temp (mixer HC1)6 modelsF.625Lead break, return temp HC26 modelsF.626Short circuit, return temp HC26 modelsF.627Lead break, return temp HC36 modelsF.628Short circuit, return temp HC36 modelsF.629Lead break, return temp HC46 modelsF.630Short circuit, return temp HC46 modelsF.685HPMU electronics-module comms error (frost protection enabled)6 modelsF.686VCMU refrigerant-circuit-controller comms errorF.687EHCU electronics-module comms errorF.770Lead break, flow temp secondary downstream of condenserF.771Short circuit, flow temp secondary downstream of condenserF.772Lead break, oil-sump tempF.773Short circuit, oil-sump tempF.788Fault, control/supply of 4/3-way valveF.7904/3-way valve motor mis-mounted or valve faultyF.791Phase L1 missing on instantaneous heating water heaterF.792Phase L2 missing on instantaneous heating water heaterF.793Phase L3 missing on instantaneous heating water heaterF.797Secondary/HC1 pump faultyF.798HC2 pump faultyF.799Secondary/HC1 pump faultyF.800HC2 pump faultyF.8014-way diverter valve faulty, no circuit reversalF.808Lower fan not runningF.812Upper fan not runningF.819Lead break, EEV16 modelsF.820Lead break, EEV26 modelsF.823Short circuit, EEV16 modelsF.824Short circuit, EEV26 modelsF.827High-limit safety cut-out responded on instantaneous heater6 modelsF.829Flow too low — outdoor-unit ball-valve filter contaminated6 modelsF.830Power supply on inverter faultyF.831Power supply on inverter faultyF.832Inverter temperature sensor faultyF.833Inverter temperature sensor faultyF.834Power supply on inverter faultyF.835Unsuitable / mis-programmed inverterF.836Overvoltage fault on inverterF.837Power supply on compressor faultyF.838Inverter control faulty6 modelsF.839Compressor blocked6 modelsF.841Compressor running unevenly (excess torque / high power draw)F.843Overvoltage shutdown, inverterF.845Unsuitable / mis-programmed inverterF.846Compressor rotating field counter-rotatingF.847Voltage error on inverterF.848Voltage error on inverterF.864Defrost attempt unsuccessfulF.865High-pressure fault (air / shut circuit / blocked pumps / dirty condenser / faulty HP sensor / setpoints too high)F.866Low-pressure fault (low refrigerant / dirty evaporator / fans blocked or faulty)F.867Float air-vent valve responded — air in circuit / faulty air-vent / refrigerant in float valve6 modelsF.876Lead break, flow sensorF.881Refrigerant-circuit safety shutdownF.912Interior temp sensor faultF.913Interior (inverter) temperature too high6 modelsF.983Internal inverter faultF.984Control of EEV1 faultyF.985Control of EEV2 faultyF.990Short circuit, secondary-circuit temp sensorF.991Lead break, secondary-circuit temp sensorF.992Short circuit, ext. heating-water/coolant buffer sensorF.993Lead break, ext. heating-water/coolant buffer sensorF.994Short circuit, ext. heating-water buffer sensorF.995Lead break, ext. heating-water buffer sensorF.996Short circuit, ext. coolant buffer sensorF.997Lead break, ext. coolant buffer sensorF.998Flow-rate signal faulty / CAN-busF.1009Oil-sump heater faultF.1010Secondary-circuit pressure sensor faultF.1011High-pressure sensor faultF.1012Low-pressure sensor faultF.1045External heat generator not readyF.10493/2-way mixing valve not switching (ext. heat gen.)F.1050Short circuit, boiler-water temp ext. heat generatorF.1051Lead break, boiler-water temp ext. heat generatorF.1054Max temp of external heat generator exceededF.1056Inverter relay faultyA.2frost protection enabledA.11heating only in some roomsA.12incorrect timeA.16compressor + heater offA.17no increased DHW hygieneA.21indoor safety valve openedA.62no pump scan HC1A.63no pump scan HC2A.65no heating HC2A.66HC1 pump not runningA.68HC2 pump not runningA.70flow too low6 modelsA.71low compressor outputA.72low compressor outputA.73low compressor outputA.74unusual noise/operationA.75unusual noise/operationA.80compressor can't startA.81COP too low / circuit offA.82unstable controlA.83no DHW heatingA.84no room heatingA.85no DHW heatingA.86no heating HC1A.87no heating HC2A.91circuit off, aux-heater onlyA.93refrigerant circuit impairedA.94refrigerant circuit impairedA.96unusual noise/operation
Knowing the code is the easy half
A code names a symptom, not a root cause. The app takes the same code and walks the fix: what to measure first, the expected values for your exact model, and a verdict that tells you when the machine isn't actually broken.
Chase a Viessmann Vitocal code on your machine →Free, no sign-up. Pick the model, put the code in, and it takes you through the chart where we hold one.
Or watch one get chased — free demo →