All fault codes

Viessmann Vitocal F.544 fault code

Viessmann Vitocal heat pumps

What the Viessmann Vitocal F.544 fault code means, from the manufacturer's own service literature, and the UK models it applies to.

What it means

Lead break, flow temp HC2 with mixer

The flow temp hc2 with mixer sensor reads open or short circuit.

Safety: Safe isolation before disconnecting sensors or working on the PCB.

Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)

Likely causes

Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p133-134.

Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)

What Viessmann says to do

Heat pump with 1 integral heating/cooling circuit:

  1. Check setting of rotary switch S1 on ADIO electronics module (e.g. EM-MX extension): See chapter "Rotary switch S1 on electronics modules".
  2. Check the sensor and connection TS1.1/TS1.2 on the ADIO electronics module: Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
  3. Check resistor R for NTC 10 kΩ on the disconnected plug. If R > 300 kΩ, replace the sensor.
  4. Replace the ADIO electronics module.

Heat pump with 2 integral heating/cooling circuits:

  1. Check the sensor and connection X17.1/X17.2 on the EHCU electronics module: Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
  2. Check resistor R for NTC 10 kΩ on the disconnected plug. If R > 300 kΩ, replace the sensor.
  3. Replace the EHCU electronics module.

Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p133-134.

UK models this code applies to

F.544 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.

Now the harder half: proving what caused it

F.544 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase F.544 on your machine →

Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.

Or watch one get chased — free demo →Prove the cause: guided investigation →

The first steps are free to try, no account. Your first full investigation is free with one.

One full investigation is free with a free account.

Download on the App Store

Or use it in your browser on any phone or laptop.

Related codes

All Viessmann Vitocal fault codes →