Viessmann Vitocal F.100 fault code

Viessmann Vitocal heat pumps

What the Viessmann Vitocal F.100 fault code means, from the manufacturer's own service literature, and the UK models it applies to.

What it means

PlusBus voltage error

PlusBus voltage error. Electronics modules connected to PlusBus are in emergency mode. No communication possible via PlusBus. Further fault messages may be present: F.91, F.92.

Safety: Safe isolation before opening terminal covers — mains present on the interconnect.

Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)

Needs double checking. This answer looks right, but the maker's book does not print it for this exact model. Check it against the unit's own book.

Likely causes

Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p126.

Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)

What Viessmann says to do

  1. Check the number of connected PlusBus subscribers: Max. 15
  2. Total length of the PlusBus cable: < 50 m
  3. Check the following connections for the PlusBus: On HPMU electronics module, terminals X2.1/X2.2 · Wall mounted indoor unit: Connection on the underside of the appliance, 5-pole connection socket on the right, terminals 74.1/74.2 Floorstanding indoor unit: Terminal area for extra low voltage (ELV) < 42 V, luster terminal for bus connections, terminals 74.1/74.2 · Connections to all other PlusBus subscribers · Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
  4. Turn off the ON/OFF switch on the indoor unit. Wait at least 2 min. Turn on the ON/OFF switch.
  5. Disconnect all connected subscribers. Replace the HPMU electronics module. Connect the subscribers one at a time.
  6. Replace faulty subscribers.

Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p126.

UK models this code applies to

Tap yours to open F.100 on that machine.

Now the harder half: proving what caused it

F.100 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase F.100 on your machine →

Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.

Or watch one get chased — free demo →Prove the cause: guided investigation →