Viessmann Vitocal F.792 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.792 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p143.
- No power supply to phase 2 of the instantaneous heating water heater
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Turn off the ON/OFF switch on the indoor unit. Wait at least 2 min. Turn on the ON/OFF switch.
- Check the following connections: Wall mounted indoor unit: 230 V~ junction box, terminals 136.1 to 136.N3 Floorstanding indoor unit: Terminal area 230 V~/400 V~, terminals 136.L1 to
- N3 Relay K7 on EHCU electronics module · High limit safety cut-out · Instantaneous heating water heater · Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage. Replace the cables if necessary.
- Check that the instantaneous heating water heater is correctly wired for 1, 2 or 3-phase mains connection. For 1 and 2-phase mains connection, check setting for output restriction (1-phase: 3 kW, 2-phase: 5 kW). If necessary repeat commissioning.
- Check power supply L2: No voltage at 136.L2: Check fuse. · No voltage at K7.2: Replace EHCU electronics module.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p143.
UK models this code applies to
F.792 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.792 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.792 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.772Lead break, oil-sump temp
- F.773Short circuit, oil-sump temp
- F.788Fault, control/supply of 4/3-way valve
- F.7904/3-way valve motor mis-mounted or valve faulty
- F.791Phase L1 missing on instantaneous heating water heater
- F.793Phase L3 missing on instantaneous heating water heater
- F.797Secondary/HC1 pump faulty
- F.798HC2 pump faulty
- F.799Secondary/HC1 pump faulty
- F.800HC2 pump faulty