Viessmann Vitocal F.7 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.7 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The cylinder temp sensor reads open or short circuit.
Safety: Safe isolation before disconnecting sensors or working on the PCB.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p120.
- Lead break, cylinder temperature sensor
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check the connection: Wall mounted indoor unit: Connection on underside of the appliance, 6-pole connection socket on the right, terminals 9 and 10 (plug 5 on HPMU electronics module) Floorstanding indoor unit: Connection X3.3/X3.4 (plug 5) on the HPMU electronics module Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
- Check resistor R for NTC 10 kΩ on the disconnected plug. If R > 300 kΩ, replace the sensor.
- Replace the HPMU electronics module.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p120.
UK models this code applies to
F.7 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.7 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.7 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.1Lead break, flow temp secondary/HC1
- F.2Short circuit, flow temp secondary/HC1
- F.3Lead break, secondary return temp
- F.4Short circuit, secondary return temp
- F.8Short circuit, cylinder temp
- F.13Lead break, outside temp (0°C substitute used)
- F.14Short circuit, outside temp (0°C substitute used)
- F.33Lead break, air-inlet temp
- F.34Short circuit, air-inlet temp
- F.74Hydraulic system pressure too low