Viessmann Vitocal F.819 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.819 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p61.
- Lead break, electronic expansion valve 1
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check connections on VCMU refrigerant circuit controller.
- Check electronic expansion valve 1 via actuator test.
- Isolate the system from the power supply. Restart the system. If the fault persists, replace electronic expansion valve 1.
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p61.
UK models this code applies to
Tap yours to open F.819 on that machine.
Now the harder half: proving what caused it
F.819 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.819 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.799Secondary/HC1 pump faulty
- F.800HC2 pump faulty
- F.8014-way diverter valve faulty, no circuit reversal
- F.808Lower fan not running
- F.812Upper fan not running
- F.820Lead break, EEV2
- F.823Short circuit, EEV1
- F.824Short circuit, EEV2
- F.827High-limit safety cut-out responded on instantaneous heater
- F.829Flow too low — outdoor-unit ball-valve filter contaminated