Viessmann Vitocal F.99 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.99 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation before opening terminal covers — mains present on the interconnect.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p53.
- Communication error PlusBus
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check the settings in the commissioning assistant. Adjust settings if required.
- Check connections at plug 74 of the HPMU electronics module.
- Wall mounted indoor unit: Check the connections at plug 74 on the connection socket on the underside of the appliance.
- Check whether components are wrongly connected.
- Isolate the system from the power supply. Restart the system. If the fault persists, replace HPMU electronics module.
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p53.
UK models this code applies to
Tap yours to open F.99 on that machine.
Now the harder half: proving what caused it
F.99 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.99 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.87Indoor safety valve opened, system pressure too high
- F.91DIO electronics-module comms error
- F.92ADIO electronics-module comms error
- F.93M2IO electronics-module comms error
- F.94SDIO electronics-module comms error
- F.100PlusBus voltage error
- F.101Short circuit, PlusBus
- F.102WiFi comms-module error
- F.103HMI programming-unit comms error
- F.104External fault-message input active (EM-EA1/DIO)