Viessmann Vitocal F.839 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.839 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation before disconnecting the compressor or testing the inverter board — capacitors hold charge.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p150.
- Compressor does not start.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check all cables connected to compressor for correct seating, contact corrosion and damage. Replace cable if required.
- Check phase connections for compressor for clockwise rotating field. Replace phase connections if required.
- Check refrigerant lines for mechanical damage. Refrigerant lines must be connected free of load and torque stress.
- Check condenser for mechanical damage. If necessary, purge the condenser.
- Check refrigerant oil for correct viscosity and charge weight. Purge the refrigerant circuit.
- Check oil sump heater on the VCMU refrigerant circuit controller: See F.1009.
- Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
- Replace the compressor.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p150.
UK models this code applies to
Tap yours to open F.839 on that machine.
Now the harder half: proving what caused it
F.839 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.839 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.834Inverter phase fault on mains side
- F.835Unsuitable / mis-programmed inverter
- F.836Load current of inverter too high (excess current)
- F.837Power supply on compressor faulty
- F.838Inverter control faulty
- F.841Compressor running unevenly (excess torque / high power draw)
- F.843Inverter overcurrent shutdown, power factor correction filter (PFC)
- F.845Unsuitable / mis-programmed inverter
- F.846Compressor rotating field counter-rotating
- F.847Inverter current sensor recognises unchanging compressor current