Compressor blocked

Safety: Safe isolation before disconnecting the compressor or testing the inverter board — capacitors hold charge.

Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)

Likely causes

Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p150.

Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)

What Viessmann says to do

  1. Check all cables connected to compressor for correct seating, contact corrosion and damage. Replace cable if required.
  2. Check phase connections for compressor for clockwise rotating field. Replace phase connections if required.
  3. Check refrigerant lines for mechanical damage. Refrigerant lines must be connected free of load and torque stress.
  4. Check condenser for mechanical damage. If necessary, purge the condenser.
  5. Check refrigerant oil for correct viscosity and charge weight. Purge the refrigerant circuit.
  6. Check oil sump heater on the VCMU refrigerant circuit controller: See F.1009.
  7. Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
  8. Replace the compressor.

Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p150.

UK models this code applies to

Tap yours to open F.839 on that machine.

Now the harder half: proving what caused it

F.839 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase F.839 on your machine →

Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.

Or watch one get chased — free demo →Prove the cause: guided investigation →

The first steps are free to try, no account. Your first full investigation is free with one.

One full investigation is free with a free account.

Download on the App Store

Or use it in your browser on any phone or laptop.

Related codes

All Viessmann Vitocal fault codes →