All fault codes

Viessmann Vitocal F.827 fault code

Viessmann Vitocal heat pumps

What it means

High-limit safety cut-out responded on instantaneous heater

Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a resistor across the + and − terminals (Gree specifies approx. 100 Ω 20 W, Toshiba approx. 100 Ω 40 W) and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.

UK models this code applies to

From the Viessmann service literature we hold (Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)) — not a scraped list.

Vitocal 150-A04 (4.0 kW)Vitocal 150-A06 (4.8 kW)Vitocal 150-A08 (5.6 kW)Vitocal 150-A10 (7.3 kW)Vitocal 150-A13 (8.1 kW)Vitocal 150-A16 (9.1 kW)

Now the harder half: proving what caused it

F.827 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase this code in the app →

Other Viessmann Vitocal codes