Viessmann Vitocal F.623 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.623 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The return temp (mixer hc1) sensor reads open or short circuit.
Safety: Safe isolation before disconnecting sensors or working on the PCB.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p58.
- Lead break, return temperature sensor
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check the settings in the commissioning assistant. Adjust settings if required.
- Check resistance value (NTC 10 kΩ) at mixer extension kit. Replace sensor if necessary.
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p58.
UK models this code applies to
Tap yours to open F.623 on that machine.
Now the harder half: proving what caused it
F.623 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.623 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.545Short circuit, flow temp HC2 with mixer
- F.546Lead break, flow temp HC3 with mixer
- F.547Short circuit, flow temp HC3 with mixer
- F.548Lead break, flow temp HC4 with mixer
- F.549Short circuit, flow temp HC4 with mixer
- F.624Short circuit, return temp (mixer HC1)
- F.625Lead break, return temp HC2
- F.626Short circuit, return temp HC2
- F.627Lead break, return temp HC3
- F.628Short circuit, return temp HC3