Viessmann Vitocal F.867 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.867 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The float air-vent valve in the outdoor unit has responded. On an R290 unit this can mean refrigerant has reached the float valve — treat as a possible refrigerant escape.
Safety: R290 is flammable. Escaping refrigerant can lead to explosion and serious injury — keep ignition sources away, ventilate, and follow Viessmann's refrigerant-escape procedure.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p64.
- Too much air in the secondary circuit during venting
- Quick-action air vent valve may be faulty
- Refrigerant present in the float air vent valve
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- If a message appears during venting: Check the quick-action air vent valve. Replace quick-action air vent valve if required.
- If a message appears during venting: Restart filling programme.
- If a message appears during operation: Isolate the system from the power supply.
- If a message appears during operation: Shut off the hydraulic connection between the indoor and outdoor unit.
- If a message appears during operation: Notify Viessmann Werke Technical Service.
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p64.
UK models this code applies to
Tap yours to open F.867 on that machine.
Now the harder half: proving what caused it
F.867 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.867 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.847Inverter current sensor recognises unchanging compressor current
- F.848Inverter current sensor recognises fluctuating compressor current
- F.864Defrost attempt unsuccessful
- F.865High-pressure fault (air / shut circuit / blocked pumps / dirty…
- F.866Low-pressure fault (low refrigerant / dirty evaporator / fans blocked…
- F.876Lead break, flow sensor
- F.881Refrigerant-circuit safety shutdown
- F.912Interior temp sensor fault
- F.913Interior (inverter) temperature too high
- F.983Internal inverter fault