Viessmann Vitocal A.71 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal A.71 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p205.
- Excess current on compressor
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check all connections to the compressor: Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage. Replace cable if necessary.
- Check the compressor parameters.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p205.
UK models this code applies to
Tap yours to open A.71 on that machine.
Now the harder half: proving what caused it
A.71 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase A.71 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- A.63no pump scan HC2
- A.65Dry run, heating circuit pump for heating/cooling circuit 2
- A.66HC1 pump not running
- A.68HC2 pump not running
- A.70flow too low
- A.72Current, power factor correction filter
- A.73Frequency deviation, compressor speed
- A.74Pressure drop in secondary circuit
- A.75Pressure spikes in secondary circuit
- A.80compressor can't start