Viessmann Vitocal F.101 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.101 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Short circuit, PlusBus. Electronics modules connected to PlusBus are in emergency mode. No communication possible via PlusBus.
Safety: Safe isolation before opening terminal covers — mains present on the interconnect.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p126.
- Short circuit PlusBus
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Turn off the ON/OFF switch on the indoor unit. Wait at least 2 min. Turn on the ON/OFF switch.
- Check the following connections for the PlusBus: On HPMU electronics module, terminals X2.1/X2.2 · Wall mounted indoor unit: Connection on the underside of the appliance, 5-pole connection socket on the right, terminals 74.1/74.2 Floorstanding indoor unit: Connection to luster terminals for BUS connections, terminals 74.1/74.2 · Connections to all other PlusBus subscribers · Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
- Disconnect all connected subscribers. Replace the HPMU electronics module. Connect the subscribers one at a time.
- Replace faulty subscribers.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p126.
UK models this code applies to
Tap yours to open F.101 on that machine.
Now the harder half: proving what caused it
F.101 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.101 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.92ADIO electronics-module comms error
- F.93M2IO electronics-module comms error
- F.94SDIO electronics-module comms error
- F.99PlusBus comms error (modules unavailable)
- F.100PlusBus voltage error
- F.102WiFi comms-module error
- F.103HMI programming-unit comms error
- F.104External fault-message input active (EM-EA1/DIO)
- F.111Lead break, liquid-gas temp heating
- F.112Short circuit, liquid-gas temp heating