Viessmann Vitocal F.820 fault code

Viessmann Vitocal heat pumps

What the Viessmann Vitocal F.820 fault code means, from the manufacturer's own service literature, and the UK models it applies to.

What it means

Lead break, EEV2

Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)

Likely causes

Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p61.

Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)

What Viessmann says to do

  1. Check connections on VCMU refrigerant circuit controller.
  2. Check electronic expansion valve 2 via actuator test.
  3. Isolate the system from the power supply. Restart the system. If the fault persists, replace electronic expansion valve 2.

Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p61.

UK models this code applies to

Tap yours to open F.820 on that machine.

Now the harder half: proving what caused it

F.820 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase F.820 on your machine →

Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.

Or watch one get chased — free demo →Prove the cause: guided investigation →

The first steps are free to try, no account. Your first full investigation is free with one.

One full investigation is free with a free account.

Download on the App Store

Or use it in your browser on any phone or laptop.

Related codes

All Viessmann Vitocal fault codes →