Viessmann Vitocal F.990 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.990 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The secondary-circuit temp sensor sensor reads open or short circuit.
Safety: Safe isolation before disconnecting sensors or working on the PCB.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p172.
- Only for heat pumps with 1 integral heating/cooling circuit: Short circuit, low loss header temperature sensor
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check the sensor at the following connections: Terminals X17.1/X17.2 on EHCU electronics module · Wall mounted indoor unit: 6-pole connection socket on underside of appliance on left, terminals 5 and 6 · Floorstanding indoor unit: Terminal area for extra low voltage (ELV) < 42 V, luster terminal for sensors, terminals 7 and 8 · Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
- Check resistor R for NTC 10 kΩ on the disconnected plug. If R < 500 Ω, replace the sensor.
- Replace EHCU electronics module.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p172.
UK models this code applies to
F.990 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.990 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.990 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.912Interior temp sensor fault
- F.913Interior (inverter) temperature too high
- F.983Internal inverter fault
- F.984Control of EEV1 faulty
- F.985Control of EEV2 faulty
- F.991Lead break, secondary-circuit temp sensor
- F.992Short circuit, ext. heating-water/coolant buffer sensor
- F.993Lead break, ext. heating-water/coolant buffer sensor
- F.994Short circuit, ext. heating-water buffer sensor
- F.995Lead break, ext. heating-water buffer sensor