Viessmann Vitocal F.790 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.790 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation before testing the valve coil — live mains present.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p142.
- Mechanical fault on 4/3-way valve, e.g. damaged valve finger or break in guide shaft
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check connections X1.1 to X1.5 on the EHCU electronics module: Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage. Replace connecting cable if necessary.
- Check voltage U between X1.2 and X1.4 on EHCU electronics module: If U = 24 V, replace 4/3-way valve. · No voltage: Replace EHCU electronics module.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p142.
UK models this code applies to
F.790 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.790 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.790 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.770Lead break, flow temp secondary downstream of condenser
- F.771Short circuit, flow temp secondary downstream of condenser
- F.772Lead break, oil-sump temp
- F.773Short circuit, oil-sump temp
- F.788Fault, control/supply of 4/3-way valve
- F.791Phase L1 missing on instantaneous heating water heater
- F.792Phase L2 missing on instantaneous heating water heater
- F.793Phase L3 missing on instantaneous heating water heater
- F.797Secondary/HC1 pump faulty
- F.798HC2 pump faulty