Viessmann Vitocal F.836 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.836 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Load current of inverter too high (excess current). Refrigerant circuit off: Inverter and compressor cannot be switched on.
Safety: Safe isolation before disconnecting the compressor or testing the inverter board — capacitors hold charge.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p149.
- Short circuit between phases · Blocked compressor armature
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check all connections to the compressor: Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage. Replace cable if necessary.
- Check phase connections for compressor for clockwise rotating field.
- Isolate the system from the power supply. Wait at least 2 min. Switch on the system.
- Replace inverter.
- Replace compressor. If necessary, inform the manufacturer's technical support.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p149.
UK models this code applies to
Tap yours to open F.836 on that machine.
Now the harder half: proving what caused it
F.836 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.836 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.831Fault, current sensor, power factor correction filter (PFC) inverter
- F.832Inverter temperature sensor faulty
- F.833Fault, temperature sensor, power factor correction filter (PFC)…
- F.834Inverter phase fault on mains side
- F.835Unsuitable / mis-programmed inverter
- F.837Power supply on compressor faulty
- F.838Inverter control faulty
- F.839Compressor blocked
- F.841Compressor running unevenly (excess torque / high power draw)
- F.843Inverter overcurrent shutdown, power factor correction filter (PFC)