Daikin fault codes and error codes
What each code means, from Daikin's own service literature, and which UK models it applies to.
Daikin split air conditioning
U4Indoor/outdoor transmission error189 modelsU0Refrigerant shortage237 modelsA5Freeze-up protection (cooling) / high-pressure control (heating)255 modelsA6Indoor fan motor fault241 modelsE7Outdoor fan motor fault178 modelsC4Indoor heat-exchanger (liquid pipe) thermistor fault244 modelsC9Room / suction air thermistor fault244 modelsJ3Discharge pipe thermistor fault280 modelsJ6Outdoor heat-exchanger thermistor fault280 modelsH9Outdoor air thermistor fault280 modelsP4Inverter radiation-fin thermistor fault297 modelsE5Compressor motor overload / overheat279 modelsE6Compressor start failure / lock296 modelsH6Compressor position-detection sensor error296 modelsL5Inverter instantaneous over-current (DC output)276 modelsF3Abnormal discharge pipe temperature276 modelsF6Abnormal high pressure / refrigerant overcharge309 modelsL4Inverter radiation-fin temperature rise178 modelsU2Supply voltage drop / imbalance189 modelsA1Indoor unit PCB fault241 modelsE1Outdoor unit PCB fault279 modelsUAIndoor/outdoor combination mismatch205 modelsH8Compressor input current (CT) system fault296 modelsEACooling / heating switching error296 modelsH0Sensor fault (compressor system)312 modelsL3Electrical parts heat fault309 models
Daikin Altherma heat pumps
7H-01Water flow problem16 modelsE3-00High pressure switch (HPS) actuated24 modelsE4-00Abnormal suction pressure32 models89-02Heat exchanger freeze-up protection (warning)12 models8H-00Abnormal increase in outlet water temperature12 models80-00Returning water temperature sensor problem41 models81-00Leaving water temperature sensor problem13 modelsC4-00Heat exchanger temperature sensor problem16 modelsCJ-02Room temperature sensor problem13 modelsC0-00Flow sensor malfunction13 modelsE1-00Outdoor unit PCB defect24 modelsAH-00Tank disinfection not completed correctly12 models7H-04Water flow problem during domestic hot water production13 models7H-05Water flow problem during heating/sampling13 models7H-06Water flow problem during cooling/defrost13 models7H-07Water flow problem. Pump deblocking active60 models7H-08Pump abnormality during operation (pump feedback)60 models81-01Mixed water thermistor abnormality38 modelsC5-00Heat exchanger thermistor abnormality35 modelsH1-00External temperature sensor problem13 modelsH9-00OU: Malfunction of outdoor air thermistor25 modelsHC-00Tank temperature sensor problem13 modelsHC-01Second tank temperature sensor problem32 modelsJ3-00OU: Malfunction of discharge pipe thermistor28 modelsJ6-00OU: Malfunction of heat exchanger thermistor25 modelsJ6-07OU: Malfunction of heat exchanger thermistor35 modelsJ8-00Malfunction of refrigerant liquid thermistor35 modelsP4-00OU: Malfunction of radiating fin temperature sensor28 modelsH0-00OU: Voltage/current sensor problem28 modelsH6-00OU: Malfunction of position detection sensor28 modelsH8-00OU: Malfunction of compressor input (CT) system28 modelsE3-24High pressure sensor abnormality35 modelsJA-00OU: Malfunction of high pressure sensor28 modelsJA-17Refrigerant pressure sensor abnormality66 modelsHJ-10Water pressure sensor abnormality32 modelsC0-01Flow sensor malfunction62 modelsC0-02Flow sensor malfunction62 modelsF6-00OU: Abnormal high pressure in cooling28 modelsFA-00OU: Abnormal high pressure, actuation of HPS28 modelsH3-00OU: Malfunction of high pressure switch (HPS)28 modelsA5-00OU: High pressure peak cut / freeze protection problem27 modelsF3-00OU: Malfunction of discharge pipe temperature28 modelsE6-00OU: Compressor startup defect28 modelsL9-00Prevention of compressor lock35 modelsL5-00OU: Inverter instantaneous overcurrent (DC)25 modelsH5-00Malfunction of compressor overload protection35 modelsE5-00OU: Overheat of inverter compressor motor25 modelsP3-00Abnormal direct current35 modelsL1-00Malfunction of INV PCB35 modelsL8-00Malfunction triggered by a thermal protection in the inverter PCB32 modelsA1-00Zero cross detection problem16 modelsL3-00OU: Electrical box temperature rise problem25 modelsL4-00OU: Malfunction of inverter radiating fin temperature rise25 models89-01Heat exchanger freeze-up protection activated during defrost (error)13 models89-03Heat exchanger freeze-up protection activated during defrost (warning)13 models89-05Heat exchanger freeze-up protection activated during cooling operation (error)40 models89-06Heat exchanger freeze-up protection activated during cooling operation (warning)40 models8F-00Abnormal increase outlet water temperature (DHW)16 models8H-01Overheating mixed water circuit31 models8H-02Overheating mixed water circuit (thermostat)32 models8H-03Overheating water circuit (thermostat)17 modelsAA-01Backup heater overheated or BUH power cable not connected13 modelsAC-00Booster heater overheated22 modelsEC-00Abnormal increase tank temperature13 modelsAJ-03Too long DHW heat-up time required13 modelsU0-00OU: Shortage of refrigerant28 modelsE9-00Malfunction of electronic expansion valve35 modelsEA-00OU: Cool/heat switchover problem28 modelsE7-00OU: Malfunction of outdoor unit fan motor28 modelsE8-00OU: Power input overvoltage28 modelsU2-00OU: Defect of power supply voltage28 modelsP1-00Open-phase power supply imbalance32 modelsU1-00Malfunction by reverse phase/open-phase32 modelsE2-00Leakage current detection error35 modelsLC-00Malfunction in communication system of outdoor unit32 modelsU4-00Indoor/outdoor unit communication problem16 modelsU5-00User interface communication problem16 modelsU7-00OU: Transmission malfunction between main CPU - INV CPU27 modelsU8-06MMI/bizone kit communication problem57 modelsU8-07P1P2 communication error32 modelsU8-02Connection with room thermostat lost32 modelsU8-03No connection with room thermostat32 modelsU8-11Connection with the Wireless gateway lost41 modelsPJ-00Capacity setting mismatch35 modelsUA-00Indoor unit, outdoor unit matching problem16 modelsUA-17Tank type problem26 modelsU8-09MMI software version / indoor unit compatibility error60 modelsU8-04Unknown USB device32 modelsU8-05File malfunction35 modelsU3-00Underfloor heating screed dryout function not completed correctly13 modelsEC-04Tank preheating35 modelsUF-00Reversed piping or bad communication wiring detection35 models
Knowing the code is the easy half
A code names a symptom, not a root cause. The app takes the same code and walks the fix: what to measure first, the expected values for your exact model, and a verdict that tells you when the machine isn't actually broken.
Chase a Daikin code on your machine →Free, no sign-up. Pick the model, put the code in, and it takes you through the chart where we hold one.
Or watch one get chased — free demo →