Viessmann Vitocal F.160 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.160 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation before opening terminal covers — mains present on the interconnect.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p55.
- CAN bus general communication fault between the affected electronics modules
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check the CAN bus cable.
- Check the CAN bus subscriber numbers.
- Isolate the system from the power supply. Restart the system. If the fault persists, replace the CAN bus cables. Replace the electronics modules if required.
Causes and measures as printed in Viessmann One Base service instructions 6194799 (3/2022), Vitocal 150-A/151-A and 250-A/252-A, p55.
UK models this code applies to
Tap yours to open F.160 on that machine.
Now the harder half: proving what caused it
F.160 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.160 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.150Short circuit, liquid-gas temp cooling (runs on substitute)
- F.151Lead break, hot-gas temp
- F.152Short circuit, hot-gas temp
- F.155Fault, electronic expansion valve 1
- F.156Fault, electronic expansion valve 2
- F.425Time sync not possible
- F.430Gateway comms error
- F.431KNX/TP gateway comms error
- F.454Wrong operating-software version across modules (HPMU/EHCU/VCMU)
- F.472Energy-meter comms error