Viessmann Vitocal F.770 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.770 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The flow temp secondary downstream of condenser sensor reads open or short circuit.
Safety: Safe isolation before disconnecting sensors or working on the PCB.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p141.
- Lead break, flow temperature sensor, secondary circuit downstream of condenser
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check connection X15.3/X15.4 on the VCMU refrigerant circuit controller: Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
- Check resistor R for NTC 10 kΩ on the disconnected plug. If R > 300 kΩ, replace the sensor.
- Replace the VCMU refrigerant circuit controller.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p141.
UK models this code applies to
F.770 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.770 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.770 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.629Lead break, return temp HC4
- F.630Short circuit, return temp HC4
- F.685HPMU electronics-module comms error (frost protection enabled)
- F.686VCMU refrigerant-circuit-controller comms error
- F.687EHCU electronics-module comms error
- F.771Short circuit, flow temp secondary downstream of condenser
- F.772Lead break, oil-sump temp
- F.773Short circuit, oil-sump temp
- F.788Fault, control/supply of 4/3-way valve
- F.7904/3-way valve motor mis-mounted or valve faulty