Viessmann Vitocal F.117 fault code
Viessmann Vitocal heat pumps
What the Viessmann Vitocal F.117 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The evaporator suction-gas temp sensor reads open or short circuit.
Safety: Safe isolation before disconnecting sensors or working on the PCB.
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
Likely causes
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p128.
- Lead break, evaporator suction gas temperature sensor
Source: Viessmann One Base service instructions 6194799 (2022), fault & warning tables (Vitocal 150-A/151-A)
What Viessmann says to do
- Check connection X20.5/X20.6 on the VCMU refrigerant circuit controller: Check wires and plugs for correct seating. · Check connections for contact corrosion. · Check cables for mechanical damage, e.g. crushing, kinking, chafing or breakage.
- Check resistor R for NTC 10 kΩ on the disconnected plug. If R > 300 kΩ, replace the sensor.
- Replace the VCMU refrigerant circuit controller.
Causes and measures as printed in Viessmann Service instructions Diagnosis 6199893 (2026-01), Vitocal 150-A/151-A/250-A/252-A, p128.
UK models this code applies to
F.117 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.117 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.117 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.102WiFi comms-module error
- F.103HMI programming-unit comms error
- F.104External fault-message input active (EM-EA1/DIO)
- F.111Lead break, liquid-gas temp heating
- F.112Short circuit, liquid-gas temp heating
- F.118Short circuit, evaporator suction-gas temp
- F.123Lead break, liquid-gas temp condenser
- F.124Short circuit, liquid-gas temp condenser
- F.147Lead break, compressor suction-gas temp
- F.148Short circuit, compressor suction-gas temp