What it means
Outlet water temperature rose abnormally during DHW production.
How to read it — controller display: Altherma error codes show directly on the user interface / main controller display — no button dance needed. (Daikin Altherma 3 M installer reference guide, §14.4.2 error-code table)
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
Likely causes
- Low flow through the DHW coil
- Diverter valve not fully stroking
- Backup or booster heater running when it should not
- Outlet sensor reading low
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
UK models this code applies to
Tap yours to open 8F-00 on that machine.
Outdoor units45
8F-00 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Outdoor units56
Now the harder half: proving what caused it
8F-00 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase 8F-00 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- 7H-04Water flow problem during domestic hot water production
- 7H-05Water flow problem during heating/sampling
- 7H-06Water flow problem during cooling/defrost
- 7H-07Water flow problem. Pump deblocking active
- 7H-08Pump abnormality during operation (pump feedback)
- 8H-00Abnormal increase in outlet water temperature
- 8H-01Overheating mixed water circuit
- 8H-02Overheating mixed water circuit (thermostat)
- 8H-03Overheating water circuit (thermostat)
- 80-00Returning water temperature sensor problem