Daikin L1-00 fault code
Daikin Altherma heat pumps
What the Daikin L1-00 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
How to read it — controller display: Altherma error codes show directly on the user interface / main controller display — no button dance needed. (Daikin Altherma 3 M installer reference guide, §14.4.2 error-code table)
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
Likely causes
- Loose, corroded or water-damaged connector on the board
- Supply fault or poor neutral presenting as a board error
- Water ingress / corrosion (outdoor boards)
- Inverter PCB memory or hardware fault
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
UK models this code applies to
Tap yours to open L1-00 on that machine.
Outdoor units64
L1-00 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Outdoor units37
Now the harder half: proving what caused it
L1-00 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase L1-00 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- J6-00OU: Malfunction of heat exchanger thermistor
- J6-07OU: Malfunction of heat exchanger thermistor
- J8-00Malfunction of refrigerant liquid thermistor
- JA-00OU: Malfunction of high pressure sensor
- JA-17Refrigerant pressure sensor abnormality
- L3-00OU: Electrical box temperature rise problem
- L4-00OU: Malfunction of inverter radiating fin temperature rise
- L5-00OU: Inverter instantaneous overcurrent (DC)
- L8-00Malfunction triggered by a thermal protection in the inverter PCB
- L9-00Prevention of compressor lock