What it means
The unit detected leakage current. Treat as an electrical safety matter, not a code to clear.
Safety: Do not repeatedly reset a leakage-current fault. Isolate and establish the cause — this is the protection that exists to prevent a shock risk.
How to read it — controller display: Altherma error codes show directly on the user interface / main controller display — no button dance needed. (Daikin Altherma 3 M installer reference guide, §14.4.2 error-code table)
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
Likely causes
- Failing heater element to earth
- Moisture ingress in a junction or gland
- Damaged cable
- Compressor motor winding breaking down to earth
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
UK models this code applies to
Tap yours to open E2-00 on that machine.
Outdoor units64
E2-00 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Outdoor units37
Now the harder half: proving what caused it
E2-00 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase E2-00 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- CJ-02Room temperature sensor problem
- E1-00Outdoor unit PCB defect
- E3-00High pressure switch (HPS) actuated
- E3-24High pressure sensor abnormality
- E4-00Abnormal suction pressure
- E5-00OU: Overheat of inverter compressor motor
- E6-00OU: Compressor startup defect
- E7-00OU: Malfunction of outdoor unit fan motor
- E8-00OU: Power input overvoltage
- E9-00Malfunction of electronic expansion valve