Daikin F6 fault code
Daikin split air conditioning
What the Daikin F6 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Daikin flags high pressure with refrigerant overcharge as the leading cause.
Safety: High-side pipework will be hot — take care.
How to read it — remote self-diagnosis, with beeps: Hold the remote's self-diagnosis button about 5 seconds until the code segment blinks, then press repeatedly to step through codes. A LONG CONTINUOUS beep from the indoor unit marks the stored code — a short or double beep means not this one. (Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, remote self-diagnosis)
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
Likely causes
- Refrigerant overcharged
- Poor condenser rejection
- Non-condensables
- Thermistor fault
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
UK models this code applies to
Tap yours to open F6 on that machine.
Wall-mounted44
Cassettes44
Ducted28
Ceiling suspended13
Floor consoles9
Floor-standing10
Indoor and outdoor pairs24
Multi-split outdoor units8
Outdoor units175
Other models39
F6 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted151
Cassettes7
Ducted7
Ceiling suspended8
Ceiling or floor3
Floor consoles8
Indoor and outdoor pairs1
Outdoor units31
Other models53
Now the harder half: proving what caused it
F6 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F6 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- E5Compressor motor overload / overheat
- E6Compressor start failure / lock
- E7Outdoor fan motor fault
- EACooling / heating switching error
- F3Abnormal discharge pipe temperature
- H0Sensor fault (compressor system)
- H6Compressor position-detection sensor error
- H8Compressor input current (CT) system fault
- H9Outdoor air thermistor fault
- J3Discharge pipe thermistor fault