Daikin U0-00 fault code
Daikin Altherma heat pumps
What the Daikin U0-00 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The unit believes it is short of refrigerant. On an F-Gas job this is a LEAK until proven otherwise — do not just top it up.
Safety: Topping up without finding the leak is both bad practice and, for units above the threshold, a regulatory problem. Establish the loss before adding refrigerant.
How to read it — controller display: Altherma error codes show directly on the user interface / main controller display — no button dance needed. (Daikin Altherma 3 M installer reference guide, §14.4.2 error-code table)
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
Likely causes
- Genuine refrigerant loss through a leak
- Restriction reading as low charge
- Faulty pressure or temperature sensing
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
UK models this code applies to
Tap yours to open U0-00 on that machine.
Outdoor units57
U0-00 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Outdoor units44
Now the harder half: proving what caused it
U0-00 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase U0-00 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- PJ-00Capacity setting mismatch
- U1-00Malfunction by reverse phase/open-phase
- U2-00OU: Defect of power supply voltage
- U3-00Underfloor heating screed dryout function not completed correctly
- U4-00Indoor/outdoor unit communication problem
- U5-00User interface communication problem
- U7-00OU: Transmission malfunction between main CPU - INV CPU
- U8-02Connection with room thermostat lost
- U8-03No connection with room thermostat
- U8-04Unknown USB device