Daikin 7H-06 fault code
Daikin Altherma heat pumps
What the Daikin 7H-06 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Flow through the plate heat exchanger was insufficient during cooling or defrost. On a heat pump the plate is the condenser, so this is a protection trip, not a nuisance.
How to read it — controller display: Altherma error codes show directly on the user interface / main controller display — no button dance needed. (Daikin Altherma 3 M installer reference guide, §14.4.2 error-code table)
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
Likely causes
- Air in the system
- Closed or partly closed valve on this circuit
- Blocked strainer or filter
- Circulation pump fault or seized
- Flow sensor reading low
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
UK models this code applies to
Tap yours to open 7H-06 on that machine.
Outdoor units35
7H-06 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Outdoor units66
Now the harder half: proving what caused it
7H-06 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase 7H-06 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- 7H-01Water flow problem
- 7H-04Water flow problem during domestic hot water production
- 7H-05Water flow problem during heating/sampling
- 7H-07Water flow problem. Pump deblocking active
- 7H-08Pump abnormality during operation (pump feedback)
- 8F-00Abnormal increase outlet water temperature (DHW)
- 8H-00Abnormal increase in outlet water temperature
- 8H-01Overheating mixed water circuit
- 8H-02Overheating mixed water circuit (thermostat)
- 8H-03Overheating water circuit (thermostat)