Daikin E5 fault code
Daikin split air conditioning
What the Daikin E5 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The inverter compressor has tripped on overload or overheat. Daikin lists refrigerant shortage among the causes.
Safety: Safe isolation before disconnecting the compressor; discharge side runs hot.
How to read it — remote self-diagnosis, with beeps: Hold the remote's self-diagnosis button about 5 seconds until the code segment blinks, then press repeatedly to step through codes. A LONG CONTINUOUS beep from the indoor unit marks the stored code — a short or double beep means not this one. (Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, remote self-diagnosis)
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
Likely causes
- Low charge overheating the compressor
- Stop valve part-closed
- High head (rejection)
- Compressor fault
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
UK models this code applies to
Tap yours to open E5 on that machine.
Wall-mounted31
Cassettes48
Ducted29
Ceiling suspended13
Ceiling or floor1
Floor consoles9
Floor-standing10
Indoor and outdoor pairs24
Multi-split outdoor units8
Outdoor units165
E5 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted164
Ducted6
Ceiling suspended8
Ceiling or floor2
Floor consoles8
Indoor and outdoor pairs1
Outdoor units41
Other models69
Now the harder half: proving what caused it
E5 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase E5 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- A5Freeze-up protection (cooling) / high-pressure control (heating)
- A6Indoor fan motor fault
- C4Indoor heat-exchanger (liquid pipe) thermistor fault
- C9Room / suction air thermistor fault
- E1Outdoor unit PCB fault
- E6Compressor start failure / lock
- E7Outdoor fan motor fault
- EACooling / heating switching error
- F3Abnormal discharge pipe temperature
- F6Abnormal high pressure / refrigerant overcharge