Daikin U2 fault code
Daikin split air conditioning
What the Daikin U2 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Power supply voltage out of range, open phase or DC-bus voltage low.
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
How to read it — remote self-diagnosis, with beeps: Hold the remote's self-diagnosis button about 5 seconds until the code segment blinks, then press repeatedly to step through codes. A LONG CONTINUOUS beep from the indoor unit marks the stored code — a short or double beep means not this one. (Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, remote self-diagnosis)
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
Likely causes
- Supply dip, surge or poor neutral
- Undersized or poorly terminated supply cable (volt drop on start)
- Lost phase / unbalanced supply (3-phase models)
- Rectifier, PFC or DC-link fault on the inverter board
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
UK models this code applies to
Tap yours to open U2 on that machine.
Wall-mounted24
Cassettes16
Ducted7
Ceiling suspended6
Ceiling or floor1
Floor consoles3
Indoor and outdoor pairs24
Multi-split outdoor units8
Outdoor units165
U2 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted171
Cassettes35
Ducted28
Ceiling suspended15
Ceiling or floor2
Floor consoles14
Floor-standing10
Indoor and outdoor pairs1
Outdoor units41
Other models72
Now the harder half: proving what caused it
U2 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase U2 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- H9Outdoor air thermistor fault
- J3Discharge pipe thermistor fault
- J6Outdoor heat-exchanger thermistor fault
- L3Electrical parts heat fault
- L4Inverter radiation-fin temperature rise
- L5Inverter instantaneous over-current (DC output)
- P4Inverter radiation-fin thermistor fault
- U0Refrigerant shortage
- U4Indoor/outdoor transmission error
- UAIndoor/outdoor combination mismatch