Daikin A5 fault code
Daikin split air conditioning
What the Daikin A5 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Daikin lists a clogged indoor filter / air short-circuit, or a faulty indoor coil thermistor. Not on Daikin's list, but the same physics: an indoor fan that never turns at all ices the coil too, and A5 is what you end up reading. If the fan is dead, chase the fan — the code is the consequence.
Safety: Isolate before working near the fan — it can restart without warning.
How to read it — remote self-diagnosis, with beeps: Hold the remote's self-diagnosis button about 5 seconds until the code segment blinks, then press repeatedly to step through codes. A LONG CONTINUOUS beep from the indoor unit marks the stored code — a short or double beep means not this one. (Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, remote self-diagnosis)
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
Likely causes
- Clogged indoor filter / restricted airflow
- Indoor fan not running at all (ices the coil)
- Air short-circuit at the indoor unit
- Indoor coil thermistor fault
- Low charge (cooling freeze-up)
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
UK models this code applies to
Tap yours to open A5 on that machine.
Wall-mounted28
Cassettes35
Ducted11
Ceiling suspended13
Ceiling or floor1
Floor consoles3
Floor-standing10
Indoor and outdoor pairs24
Multi-split outdoor units8
Outdoor units181
A5 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted167
Cassettes16
Ducted24
Ceiling suspended8
Ceiling or floor2
Floor consoles14
Indoor and outdoor pairs1
Outdoor units25
Other models73
Now the harder half: proving what caused it
A5 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase A5 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- A1Indoor unit PCB fault
- A6Indoor fan motor fault
- C4Indoor heat-exchanger (liquid pipe) thermistor fault
- C9Room / suction air thermistor fault
- E1Outdoor unit PCB fault
- E5Compressor motor overload / overheat
- E6Compressor start failure / lock
- E7Outdoor fan motor fault
- EACooling / heating switching error
- F3Abnormal discharge pipe temperature