Daikin U8-07 fault code
Daikin Altherma heat pumps
What the Daikin U8-07 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The P1/P2 bus between the user interface and the unit has failed. Check polarity and cable length as well as continuity.
Safety: Safe isolation before opening terminal covers — mains present on the interconnect.
How to read it — controller display: Altherma error codes show directly on the user interface / main controller display — no button dance needed. (Daikin Altherma 3 M installer reference guide, §14.4.2 error-code table)
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
Likely causes
- Miswired or broken interconnect
- Supply fault
- Outdoor control PCB
- Indoor control PCB
Source: Daikin Altherma 3 M installer reference guide 4P685228-1B §14.4.2
UK models this code applies to
Tap yours to open U8-07 on that machine.
Outdoor units54
U8-07 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Outdoor units47
Now the harder half: proving what caused it
U8-07 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase U8-07 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- U4-00Indoor/outdoor unit communication problem
- U5-00User interface communication problem
- U7-00OU: Transmission malfunction between main CPU - INV CPU
- U8-02Connection with room thermostat lost
- U8-03No connection with room thermostat
- U8-04Unknown USB device
- U8-05File malfunction
- U8-06MMI/bizone kit communication problem
- U8-09MMI software version / indoor unit compatibility error
- U8-11Connection with the Wireless gateway lost