Daikin prints this as a DC current sensor fault (CTXM/FTXM-M operation manual). It is a current sensor, not a temperature sensor.
Safety: Safe isolation before disconnecting sensors or working on the PCB.
How to read it — remote self-diagnosis, with beeps: Hold the remote's self-diagnosis button about 5 seconds until the code segment blinks, then press repeatedly to step through codes. A LONG CONTINUOUS beep from the indoor unit marks the stored code — a short or double beep means not this one. (Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, remote self-diagnosis)
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
Likely causes
Causes as printed in Daikin's Perfera R32 service manual (ESIE20-11A, RXM20~71R(9) / FTXM20~71R), §2.5.21 "H8-00 Malfunction of compressor input system", PDF p24. That book covers the Perfera R range only, not every Daikin wall unit.
- Faulty main PCB
- Faulty compressor or miswiring of the compressor power supply cable
- Faulty reactor
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
UK models this code applies to
Tap yours to open H8 on that machine.
Wall-mounted31
Cassettes44
Ducted28
Ceiling suspended13
Floor consoles9
Floor-standing10
Indoor and outdoor pairs24
Multi-split outdoor units8
Outdoor units175
H8 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted164
Cassettes7
Ducted7
Ceiling suspended8
Ceiling or floor3
Floor consoles8
Indoor and outdoor pairs1
Outdoor units31
Other models69
Now the harder half: proving what caused it
H8 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase H8 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- EACooling / heating switching error
- F3Abnormal discharge pipe temperature
- F6Abnormal high pressure / refrigerant overcharge
- H0Sensor fault (compressor system)
- H6Compressor position-detection sensor error
- H9Outdoor air thermistor fault
- J3Discharge pipe thermistor fault
- J6Outdoor heat-exchanger thermistor fault
- L3Electrical parts heat fault
- L4Inverter radiation-fin temperature rise