Daikin A1 fault code
Daikin split air conditioning
What the Daikin A1 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
How to read it — remote self-diagnosis, with beeps: Hold the remote's self-diagnosis button about 5 seconds until the code segment blinks, then press repeatedly to step through codes. A LONG CONTINUOUS beep from the indoor unit marks the stored code — a short or double beep means not this one. (Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, remote self-diagnosis)
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
Likely causes
- Loose, corroded or water-damaged connector on the board
- Supply fault or poor neutral presenting as a board error
- Water ingress / corrosion (outdoor boards)
- Indoor main PCB memory or hardware fault
Source: Daikin CTXM/FTXM-M operation manual 3PEN393186-10J, malfunction-code table (remote self-diagnosis)
UK models this code applies to
Tap yours to open A1 on that machine.
Wall-mounted31
Cassettes35
Ducted8
Ceiling suspended13
Ceiling or floor1
Floor consoles3
Floor-standing10
Indoor and outdoor pairs24
Multi-split outdoor units8
Outdoor units167
A1 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted164
Cassettes16
Ducted27
Ceiling suspended8
Ceiling or floor2
Floor consoles14
Indoor and outdoor pairs1
Outdoor units39
Other models73
Now the harder half: proving what caused it
A1 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase A1 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- A5Freeze-up protection (cooling) / high-pressure control (heating)
- A6Indoor fan motor fault
- C4Indoor heat-exchanger (liquid pipe) thermistor fault
- C9Room / suction air thermistor fault
- E1Outdoor unit PCB fault
- E5Compressor motor overload / overheat
- E6Compressor start failure / lock
- E7Outdoor fan motor fault
- EACooling / heating switching error
- F3Abnormal discharge pipe temperature