Vaillant aroTHERM F.733 fault code
Vaillant aroTHERM heat pumps
What the Vaillant aroTHERM F.733 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The refrigerant is evaporating below the compressor's operating envelope. The manual's stated cause: insufficient air volume flow through the evaporator.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
Likely causes
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p58.
- Insufficient air volume flow through the outdoor unit's heat exchanger (heating mode) leads to an insufficient energy input in the environment circuit (heating mode) or building circuit (cooling mode)
- Refrigerant volume too low
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
What Vaillant says to do
- If the building circuit contains thermostatic valves, check that they are suitable for cooling mode (check volume flow in cooling mode)
- Check the fan unit for dirt
- Check the EEV (does the EEV move to the limit stop? Use the sensor/actuator test)
- Check the compressor inlet sensor
- Check the refrigerant volume
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p58.
UK models this code applies to
Tap yours to open F.733 on that machine.
Now the harder half: proving what caused it
F.733 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.733 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.718Fan unit 1 blocked
- F.723Building circuit: pressure too low
- F.729Compressor outlet temperature too low
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.734Condensation temperature too low
- F.735Evaporation temperature too high
- F.737Condensation temperature too high
- F.741Building-circuit return temperature too low (during de-icing)
- F.752Fault: frequency converter