Vaillant aroTHERM F.737 fault code
Vaillant aroTHERM heat pumps
What the Vaillant aroTHERM F.737 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Condensing above the operating envelope. The manual's stated causes: the environment circuit (cooling mode) or building circuit (heating mode) is too hot for compressor operation, or external heat is being fed into the circuit.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
Likely causes
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p59.
- Temperature in the environment circuit (cooling mode) or building circuit (heating mode) too high for compressor operation
- Feed-in of external heat into the building circuit
- Refrigerant circuit overfilled
- Insufficient flow rate in the building circuit
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
What Vaillant says to do
- Reduce or stop the external heat that is entering
- Check the back-up heater (heats up even though it is off in the sensor/actuator test?)
- Check the EEV (does the EEV move to the limit stop? Use the sensor/actuator test)
- Check the compressor outlet sensor, compressor outlet temperature sensor (TT135) and high-pressure sensor
- Check the refrigerant filling volume for overfilling
- Check whether the service valves on the outdoor unit are open.
- Check the air volume flow in cooling mode for sufficient flow rate
- Checking the heating pump
- Check the building circuit flow rate
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p59.
UK models this code applies to
Tap yours to open F.737 on that machine.
Now the harder half: proving what caused it
F.737 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.737 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.733Evaporation temperature too low
- F.734Condensation temperature too low
- F.735Evaporation temperature too high
- F.741Building-circuit return temperature too low (during de-icing)
- F.752Fault: frequency converter
- F.753Connection fault: frequency converter not recognised
- F.7554-port valve position incorrect
- F.774Air inlet temperature sensor