Vaillant aroTHERM F.729 fault code
Vaillant aroTHERM heat pumps
What the Vaillant aroTHERM F.729 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Compressor-outlet temperature stayed below 0 °C for more than 10 minutes, or fell below −10 °C while in the operating envelope — usually liquid returning to the compressor (flooding).
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
Likely causes
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p57.
- The compressor outlet temperature is lower than 0 °C for more than 10 minutes or the compressor outlet temperature is lower than -10 °C even though the heat pump is in the operating characteristics.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
What Vaillant says to do
- Checking the high-pressure sensor
- Checking that the EEV is working correctly
- Check the condenser outlet temperature sensor (subcooling)
- Check whether the 4-port diverter valve is in the intermediate position
- Checking the refrigerant volume for overfilling
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p57.
UK models this code applies to
Tap yours to open F.729 on that machine.
Now the harder half: proving what caused it
F.729 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.729 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.546High-pressure sensor fault
- F.582Electronic expansion valve fault
- F.585Condenser outlet temperature sensor fault
- F.718Fan unit 1 blocked
- F.723Building circuit: pressure too low
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.733Evaporation temperature too low
- F.734Condensation temperature too low
- F.735Evaporation temperature too high