Vaillant aroTHERM F.732 fault code
Vaillant aroTHERM heat pumps
What it means
Compressor outlet temperature too high
Discharge (compressor-outlet, TT135) temperature has exceeded 130 °C — application limits exceeded, the EEV not opening correctly, or the refrigerant charge too low (frequent defrost).
Safety: R290 (propane) — A3 flammable. Leak-check with suitable equipment; no ignition sources; ventilate.
UK models this code applies to
From the Vaillant service literature we hold (Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table) — not a scraped list.
Now the harder half: proving what caused it
F.732 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.