Vaillant aroTHERM F.723 fault code
Vaillant aroTHERM heat pumps
What the Vaillant aroTHERM F.723 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
System water pressure in the building circuit has fallen too low. Related to F.022 — treat a repeating loss as a leak, not a top-up job.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
Likely causes
- Genuine leak on the building circuit
- System not filled to the correct pressure
- Expansion vessel failed or wrong charge pressure
- Pressure sensor reading false (see F.073)
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
UK models this code applies to
Tap yours to open F.723 on that machine.
Now the harder half: proving what caused it
F.723 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.723 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.526EEV outlet temperature sensor fault
- F.546High-pressure sensor fault
- F.582Electronic expansion valve fault
- F.585Condenser outlet temperature sensor fault
- F.718Fan unit 1 blocked
- F.729Compressor outlet temperature too low
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.733Evaporation temperature too low
- F.734Condensation temperature too low