Vaillant aroTHERM F.735 fault code
Vaillant aroTHERM heat pumps
What the Vaillant aroTHERM F.735 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Evaporating above the operating envelope. The manual's stated cause: the temperature in the environment (air) circuit is too high for compressor operation.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
Likely causes
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p58.
- Temperature in the environment circuit (heating mode) or building circuit (cooling mode) too high for compressor operation
- Feed-in of external heat into the environment circuit too high due to increased fan speed
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
What Vaillant says to do
- Check the system temperatures
- Check the refrigerant filling volume for overfilling
- Check the EEV (does the EEV move to the limit stop? Use sensor/actuator test)
- Check the sensor for the evaporation temperature (depending on the position of the 4-port diverter valve)
- Check the volume flow in cooling mode
- Check the air volume flow in heating mode
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p58.
UK models this code applies to
Tap yours to open F.735 on that machine.
Now the harder half: proving what caused it
F.735 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.735 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.729Compressor outlet temperature too low
- F.731High-pressure switch open
- F.732Compressor outlet temperature too high
- F.733Evaporation temperature too low
- F.734Condensation temperature too low
- F.737Condensation temperature too high
- F.741Building-circuit return temperature too low (during de-icing)
- F.752Fault: frequency converter
- F.753Connection fault: frequency converter not recognised
- F.7554-port valve position incorrect