What it means
Block 02 (outdoor PCB). The relation between voltage, current and frequency is abnormal — the compressor is overloaded (over-charge, PMV failure) or failing on high current.
Safety: Safe isolation before working on the inverter board — capacitors hold charge.
Source: Toshiba service manual SVM-19001-3 (Seiya) / SVM-20015-4 (Shorai Edge) §11-4, Table 11-4-1
UK models this code applies to
Tap yours to open 1C on that machine.
Wall-mounted49
Cassettes17
Ducted10
Ceiling suspended10
Floor consoles1
Floor-standing4
Indoor and outdoor pairs1
Outdoor units87
Other models30
1C on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted33
Ducted10
Multi-split outdoor units13
Now the harder half: proving what caused it
1C names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase 1C on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Related codes
- 0CTA room sensor short-circuit or disconnection
- 0dTC indoor heat-exchanger sensor fault
- 01OPERATION + TIMER (White) flashing 5 Hz: connecting cable / serial…
- 1AOutdoor fan motor fault
- 1bTO outside-air sensor fault
- 1dCompressor does not rotate
- 1EDischarge temperature exceeded 117 °C
- 1FCompressor high current at minimum frequency
- 02OPERATION lamp flashing 5 Hz: protective circuit, OUTDOOR P.C. board
- 03OPERATION + TIMER flashing 5 Hz: protective circuit, OTHERS…