Vaillant aroTHERM F.1117 fault code
Vaillant aroTHERM heat pumps
What the Vaillant aroTHERM F.1117 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a suitable resistor across the + and − terminals and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
Likely causes
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p61.
- Defective fuse
- Incorrect electrical connections
- Mains voltage too low
- Compressor/low tariff power supply not connected
- Energy supply company lockout for longer than three hours
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
What Vaillant says to do
- Check the fuse
- Checking the electrical connections
- Check the voltage at the heat pump electrical connection
- Reduce energy supply company anti-cycling time to under three hours
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p61.
UK models this code applies to
Tap yours to open F.1117 on that machine.
F.1117 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.1117 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.1117 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.785Fan unit 2 blocked
- F.788Building circuit pump fault
- F.817Frequency converter fault: compressor
- F.818Frequency converter: mains voltage fault
- F.819Frequency converter fault: overheating
- F.820Connection fault: building circuit pump
- F.821Immersion heater flow sensor fault
- F.825Condenser inlet temperature sensor fault
- F.1100Immersion heater: safety cut-out
- F.1120Heating rod: phase failure