Vaillant aroTHERM F.817 fault code
Vaillant aroTHERM heat pumps
What the Vaillant aroTHERM F.817 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The frequency converter reports a compressor drive fault (F.818 mains voltage, F.819 overheating are siblings).
Safety: Safe isolation before working on the inverter — capacitors hold charge.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
Likely causes
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p60.
- Defect in the compressor (e.g. short circuit)
- Defect in the frequency converter
- Connection cable to the compressor is defective or loose
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
What Vaillant says to do
- Measure the winding resistance in the compressor
- Measure the frequency converter output between the three phases, (it must be > 1 kΩ)
- Check the wiring harness and plug connections
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p60.
UK models this code applies to
Tap yours to open F.817 on that machine.
F.817 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.817 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.817 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.753Connection fault: frequency converter not recognised
- F.7554-port valve position incorrect
- F.774Air inlet temperature sensor
- F.785Fan unit 2 blocked
- F.788Building circuit pump fault
- F.818Frequency converter: mains voltage fault
- F.819Frequency converter fault: overheating
- F.820Connection fault: building circuit pump
- F.821Immersion heater flow sensor fault
- F.825Condenser inlet temperature sensor fault