All fault codes

Vaillant aroTHERM F.818 fault code

Vaillant aroTHERM heat pumps

What it means

Frequency converter: mains voltage fault

The frequency converter has seen the mains outside its window. Healthy running range is 195–253 V; the converter faults if the supply falls outside 70–282 V. Check the incoming supply is stable and within range before condemning the inverter.

Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a resistor across the + and − terminals (Gree specifies approx. 100 Ω 20 W, Toshiba approx. 100 Ω 40 W) and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.

UK models this code applies to

From the Vaillant service literature we hold (Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table) — not a scraped list.

aroTHERM plus VWL 35/6aroTHERM plus VWL 55/6aroTHERM plus VWL 75/6aroTHERM plus VWL 105/6aroTHERM plus VWL 125/6

Now the harder half: proving what caused it

F.818 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase this code in the app →

Other Vaillant aroTHERM codes