Vaillant aroTHERM F.788 fault code
Vaillant aroTHERM heat pumps
What the Vaillant aroTHERM F.788 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The heating circuit pump is faulty or not responding (see also F.820 connection fault).
Safety: Isolate before working on the pump.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
Likely causes
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p60.
- The electronics system of the high-efficiency pump has detected a fault (e.g. dry running, blockage, overvoltage, undervoltage) and has switched off and locked the pump.
Source: Vaillant hydraulic station installation & maintenance instructions 0020257319 (VWL 57…127/5 IS), fault-message table
What Vaillant says to do
- Switch the heat pump off for at least 30 seconds (no current)
- Check the quality of the plug contact on the PCB
- Check that the pump functions correctly
- Purging the building circuit
- Check that the dirt filter that is in place is permeable
Causes and remedies as printed in Vaillant 0020257319_05 (hydraulic station VWL 57…127/5 IS), Appendix I Fault codes, PDF p60.
UK models this code applies to
Tap yours to open F.788 on that machine.
F.788 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
F.788 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase F.788 on your machine →Free, no sign-up. We don't hold a chart for this code yet — pick the model for its manual section.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- F.752Fault: frequency converter
- F.753Connection fault: frequency converter not recognised
- F.7554-port valve position incorrect
- F.774Air inlet temperature sensor
- F.785Fan unit 2 blocked
- F.817Frequency converter fault: compressor
- F.818Frequency converter: mains voltage fault
- F.819Frequency converter fault: overheating
- F.820Connection fault: building circuit pump
- F.821Immersion heater flow sensor fault