All fault codes

Gree U8 fault code

Gree air conditioning

What the Gree U8 fault code means, from the manufacturer's own service literature, and the UK models it applies to.

What it means

Zero-crossing detection circuit fault

The mains zero-crossing detection circuit is not reading correctly.

Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a resistor across the + and − terminals (Gree specifies approx. 100 Ω 20 W) and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.

Source: Gree (Zhuhai) Service Manual, Bora Inverter R32 §9.1 Error Code List

UK models this code applies to

Tap yours to open U8 on that machine.

U8 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.

Now the harder half: proving what caused it

U8 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase U8 on your machine →

Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.

Or watch one get chased — free demo →
Download on the App Store

Or use it in your browser on any phone or laptop.

Related codes

All Gree fault codes →