Gree U1 fault code
Gree air conditioning
What the Gree U1 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The current-sensing circuit for the compressor is faulty — the drive cannot trust its own current reading.
Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a resistor across the + and − terminals (Gree specifies approx. 100 Ω 20 W) and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.
Source: Gree (Zhuhai) Service Manual, Bora Inverter R32 §9.1 Error Code List
UK models this code applies to
Tap yours to open U1 on that machine.
Cassettes8
Ducted16
Ceiling or floor8
Indoor and outdoor pairs9
U1 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Now the harder half: proving what caused it
U1 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase U1 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Related codes
- JFDetecting plate (WiFi module) fault
- L3Outdoor DC fan motor fault
- LCCompressor fails to start
- P5Phase-current overcurrent protection
- P7Module (IPM) temperature sensor open/short
- P8Inverter module temperature protection
- PHDC bus bar high-voltage protection
- PLDC bus bar low-voltage protection
- PUDC link capacitor charging fault
- U8Zero-crossing detection circuit fault