Gree P8 fault code
Gree air conditioning
What the Gree P8 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
The IPM has reached its temperature limit and the unit has protected itself.
Safety: Safe isolation and capacitor discharge before touching the inverter boards.
Source: Gree (Zhuhai) Service Manual, Bora Inverter R32 §9.1 Error Code List
UK models this code applies to
Tap yours to open P8 on that machine.
P8 on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.
Wall-mounted4
Cassettes8
Ducted16
Ceiling or floor8
Floor consoles3
Indoor and outdoor pairs3
Outdoor units4
Now the harder half: proving what caused it
P8 names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase P8 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Related codes
- JFDetecting plate (WiFi module) fault
- L3Outdoor DC fan motor fault
- LCCompressor fails to start
- P5Phase-current overcurrent protection
- P7Module (IPM) temperature sensor open/short
- PHDC bus bar high-voltage protection
- PLDC bus bar low-voltage protection
- PUDC link capacitor charging fault
- U1Compressor phase-current detection circuit fault
- U8Zero-crossing detection circuit fault