All fault codes

Gree PU fault code

Gree air conditioning

What the Gree PU fault code means, from the manufacturer's own service literature, and the UK models it applies to.

What it means

DC link capacitor charging fault

The DC link capacitors are not charging correctly at start-up. One measurement across the DC link settles this before anything is replaced.

Safety: DANGER: the DC link holds a lethal charge. This flow asks you to measure it LIVE — if you are not equipped and competent to take a live DC measurement inside the outdoor unit, isolate, discharge through a resistor (approx. 100 Ω 20 W across + and −, per Gree) and treat the fault as a board fault instead. Never short the terminals with a screwdriver.

Source: Gree (Zhuhai) Service Manual, Bora Inverter R32 §9.1 Error Code List

UK models this code applies to

Tap yours to open PU on that machine.

PU on these comes from each model's own manual, which may not match the meaning above — tap yours to read it.

Wall-mounted4
Cassettes8
Ducted16
Ceiling or floor8
Floor consoles3
Indoor and outdoor pairs3
Outdoor units4

Now the harder half: proving what caused it

PU names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.

Chase PU on your machine →

Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.

Or watch one get chased — free demo →
Download on the App Store

Or use it in your browser on any phone or laptop.

Related codes

All Gree fault codes →