Gree PL fault code

Gree air conditioning

What it means

DC bus bar low-voltage protection

DC link voltage dropped below the safe operating window.

Safety: Safe isolation, then TREAT THE DC LINK AS LIVE. The electrolytic capacitors hold a lethal charge after the supply is off. Discharge through a resistor across the + and − terminals (Gree specifies approx. 100 Ω 20 W, Toshiba approx. 100 Ω 40 W) and confirm with a meter on DC before touching the board. Never short the terminals with a screwdriver.

UK models this code applies to

From the Gree service literature we hold (Gree (Zhuhai) Service Manual, Bora Inverter R32 §9.1 Error Code List) — not a scraped list.

Bora GWH09AAB (9k)Bora GWH12AAB (12k)Bora GWH18AAD (18k)Bora GWH24AAD (24k)Free Match GWHD(18)NK6LOFree Match GWHD(21)NK6LOFree Match GWHD(24)NK6LOFree Match GWHD(28)NK6LO

Now the harder half: proving what caused it

PL names a symptom, not a root cause. In the app, the same code opens a guided investigation: what to measure first, the expected values for your exact model, and an honest verdict — including “nothing in this machine is broken” when that's what the readings say.