Mitsubishi Ecodan L9 error code
Mitsubishi Ecodan heat pumps
What the Mitsubishi Ecodan L9 fault code means, from the manufacturer's own service literature, and the UK models it applies to.
What it means
Flow sensor reads low for 10 s (ignored for the first minute after pump start). Request code 569 = 1: heat-source side. On the FTC, LP stands for the Legionella prevention mode: this code can be raised while that mode is running (OCH571A p.42 key).
How to read it — ftc controller: Ecodan check codes show on the FTC / main controller display. (Ecodan service manual OCH727, §9-2 self-diagnosis action table)
Source: Ecodan FTC service manual §10-4 self-diagnosis and action + §10-6 checking component parts' function (pump curves, recommended water flow range, thermistor tables)
Likely causes
- Insufficient pump head
- Air / blocked strainer / leak
- Valve not open
- Flow sensor or CN1A wiring
- SW2-2 setting
- FTC board
Source: Ecodan FTC service manual §10-4 self-diagnosis and action + §10-6 checking component parts' function (pump curves, recommended water flow range, thermistor tables)
UK models this code applies to
Tap yours to open L9 on that machine.
Outdoor units44
Now the harder half: proving what caused it
L9 names a symptom, not a root cause. Pick your model and the wizard takes this code one question at a time. To prove the cause, the guided investigation asks what to measure and ends on an honest verdict — including “nothing in this machine is broken” when that's what the readings say.
Chase L9 on your machine →Free, no sign-up. Pick the model: where we hold a chart for it, it takes you through one question at a time.
Or watch one get chased — free demo →Prove the cause: guided investigation →The first steps are free to try, no account. Your first full investigation is free with one.
One full investigation is free with a free account.
Related codes
- L3Circulation water overheat protection (≥80 °C)
- L4DHW tank overheat protection (THW5 ≥75 °C)
- L5Water-circuit thermistor (THW1/2/5/6/7/8/9) open/short
- L6Circulation water freeze protection
- L8Heating operation error (no temperature rise)
- LDBoiler flow/return thermistor (THWB1/THWB2) open/short
- P1Room temperature thermistor (TH1A/TH1B) open/short
- P2Liquid refrigerant thermistor (TH2) open/short
- P6Plate heat-exchanger freeze protection
- P8Refrigerant circuit abnormality